Program
No.
Program Name
Input Data
Default
20-02-05
System Options for Multiline Telephones - Head-
set Busy Mode
0 = No (Disable)
1 = Yes (Enable)
0
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15
Extension 101 is Class
15 and other Extension
are Class 1
20-13-06
Class of Service Options (Supplementary Serv-
ice) - Automatic Off-Hook Signaling (Automatic
Override)
0 = Off (manually)
1 = On (automatically)
COS 01 ~ 15 = 1
20-13-33
Class of Service Options (Supplementary Serv-
ice) - ACD Supervisor's Position Enhancement
0 = Off
1 = On
0
20-13-39
Class of Service Options (Supplementary Serv-
ice) - ACD Queue Status Display
0 = Off
1 = On
COS 01 ~ 15 = 0
30-05-04
DSS Console Lamp Table - ACD Agent Busy
0 ~ 7 (Lamp Pattern Data)
7
30-05-05
DSS Console Lamp Table - Out of Schedule
(ACD DSS)
0 ~ 7 (Lamp Pattern Data)
0
30-05-06
DSS Console Lamp Table - ACD Agent log Out
(ACD DSS)
0 ~ 7 (Lamp Pattern Data)
5
30-05-07
DSS Console Lamp Table - ACD Agent Log In
(ACD DSS)
1 ~ 7 (Lamp Pattern Data)
4
41-01-01
System Options for ACD - System Supervisory
Extension
Up to eight digits (0 ~ 9,
*
, #)
No Setting
41-01-02
System Options for ACD - Login ID Code Digit
0 ~ 20
0 = No Login ID
0
41-01-03
System Options for ACD - ACD MIS Connection
Ports
0 = Not Set
3 = LAN (CPU)
0
41-01-04
System Options for ACD - ACD MIS Notification
when ACD Call receives Busy
0 = Notifies
1 = No notification
0
41-01-05
System Options for ACD - ACD MIS Output For-
mat
0 = Classic
1 = 8-digit DDI Field
2 = Extra DDI Event
3 = XML Format
0
41-02-01
ACD Group and Agent Assignments - ACD
Group No.
ACD Work Period Mode Number:
1 ~ 8
ACD Group Number: 0 ~ 8 (0 =
No Setting)
0
41-03-01
Incoming Ring Group Assignment for ACD
Group - ACD Group Number
0 ~ 2
0 = No Setting
0
41-03-02
Incoming Ring Group Assignment for ACD
Group - Night Announcement Service
0 = No
1 = Yes
0
41-03-03
Incoming Ring Group Assignment for ACD
Group - Priority Data
0, 1 ~ 7
0 = No Priority
1 = Highest Priority
7 = Lowest Priority
0
41-04-01
Group Supervisory Station Setup - Group Super-
visory Extension
Up to eight digits (0 ~ 9,
*
, #)
No Setting
41-04-02
Group Supervisory Station Setup - Operation
Type
0 = Do Not receive any ACD
Group incoming calls (No)
1 = Receive ACD Group incom-
ing calls in case of overflow
(Busy)
2 = Receive ACD Group incom-
ing calls all the time (Yes)
0
41-05-01
ACD Agent Work Schedules
Work Period Mode Number = 1 ~
8
Start Time = 0000 ~ 2359
End Time = 0000 ~ 2359
(Start) 0000
(End) 0000
ISSUE 1.0
SL2100
Features and Specifications Manual
1-69
A
Summary of Contents for UNIVERGE SL2100
Page 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Page 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Page 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Page 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Page 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Page 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Page 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Page 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Page 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Page 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Page 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...
Page 978: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...