Program
No.
Program Name
Input Data
Default
20-13-10
Class of Service Options (Supplementary Serv-
ice) - Barge-In Monitor
0 = Speech
1 = Monitor
COS 01 ~ 15 = 0
24-02-07
System Options for Transfer - Trunk-to-Trunk
Transfer Release Warning Tone
0 ~ 64800 seconds
1800
24-02-10
System Options for Transfer - Disconnect Trunk-
to-Trunk
0 ~ 64800 seconds
0
25-07-07
System Timers for VRS/DISA - Long Conversa-
tion Warning Tone Time
0 ~ 64800 seconds
1800
25-07-08
System Timers for VRS/DISA - Long Conversa-
tion Disconnect Time
0 ~ 64800 seconds
30
Method B - Tandem Trunking with Transfer Key
Program
No.
Program Name
Input Data
Default
14-01-04
Basic Trunk Data Setup - Transmit Gain Level for
Conference and Transfer Calls
1 ~ 57
(-15.5 dB ~ +12.5 dB in 0.5 dB
intervals)
32 (0 dB)
14-01-05
Basic Trunk Data Setup - Receive Gain Level for
Conference and Transfer Calls
1 ~ 57
(-15.5 dB ~ +12.5 dB in 0.5 dB
intervals)
32 (0 dB)
14-01-13
Basic Trunk Data Setup - Trunk-to-Trunk Trans-
fer
0 = Disable (No)
1 = Enable (Yes)
1
14-02-12
Analog Trunk Data Setup - Detect Network Dis-
connect Signal
0 = Disable (No)
1 = Enable (Yes)
0
15-07-01
Programmable Function Keys
-
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
1 ~ 15
Extension 101 is Class
15 and other Extension
are Class 1
20-07-11
Class of Service Options (Administrator Level) -
Forced Trunk Disconnect (analog trunk only)
0 = Off
1 = On
COS1 ~ 14/COS15 = 1
20-11-14
Class of Service Options (Hold/Transfer Service)
- Trunk-to-Trunk Transfer Restriction
0 = Off
1 = On
COS 01 ~ 15 = 0
20-11-21
Class of Service Options (Hold/Transfer Service)
- Restriction for Tandem Trunking on Hang Up
0 = Allow
1 = Deny
COS 01 ~ 15 = 0
20-13-10
Class of Service Options (Supplementary Serv-
ice) - Barge-In Monitor
0 = Speech
1 = Monitor
COS 01 ~ 15 = 0
24-02-07
System Options for Transfer - Trunk-to-Trunk
Transfer Release Warning Tone
0 ~ 64800 seconds
1800
24-02-10
System Options for Transfer - Disconnect Trunk-
to-Trunk
0 ~ 64800 seconds
0
25-07-07
System Timers for VRS/DISA - Long Conversa-
tion Warning Tone Time
0 ~ 64800 seconds
1800
25-07-08
System Timers for VRS/DISA - Long Conversa-
tion Disconnect Time
0 ~ 64800 seconds
30
81-01-03
CO Initial Data Setup - Clear Signal (Open Loop)
Detection Time
1 ~ 255
(5 ~ 1275 ms)
62 (310 ms)
ISSUE 1.0
SL2100
Features and Specifications Manual
1-819
T
Summary of Contents for UNIVERGE SL2100
Page 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Page 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Page 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Page 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Page 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Page 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Page 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Page 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Page 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Page 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Page 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...
Page 978: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...