ND-70348 (E)
CHAPTER 4
Page 116
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
–
511
DATA
(DATA)
00
–
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
76
0
b
0
Not used
Table Development:
Common or Separate
Day/Night Data Tables.
Note:
When data ta-
bles are desig-
nated as
“Common”, the
Day mode des-
ignation must
be used in the
respective com-
mands.
0
b
1
Same Special Access Code Data
(ASPS command)
0/1 = Common/Separate
b
2
Call Forwarding Service by Call-
ing Number Data (AFCP com-
mand)
0/1 = Common/Separate
0
b
3
Not used
0
b
4
0
b
5
0
b
6
0
b
7
77
b
0
Day/Night mode change via the Attendant Console handset
jack
0/1 = Not Required/Required
0
b
1
Not used
b
2
MW Refresh 0/1 = Required/Not Required
Note:
When message Waiting Lamp is provided, this data
should be assigned “0”.
1
b
3
Service Module Interface 0/1 = Required/Not Required
1
b
4
Module in which PFT card is mounted
PIM (Always assign “11”.)
1
b
5
0
b
6
Not used
0
b
7