ND-70348 (E)
CHAPTER 4
Page 149
Revision 3.0
ASYD
Note 1:
If data of bit 7 is 1 or bit 3 is 1, bits 0, 1, 2 of index 164 must be enabled for the number of digits.
Note 2:
Max. 8 ports (port 0 through 7)
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
164
b
0
Number of Digits in Maid ID Code
(for Hotel
system)
b
1
b
2
b
3
ID Code for setting/canceling Maid Status
Note 1
0/1 = Not Required/Required
b
4
Number of Digits for Group Code (PMS option)
b
5
b
6
b
7
ID Code for setting/canceling Automatic Wake-Up or
Group Announcement from a Special Admin. Station
0/1 = Not Required/Required
Note 1
165
b
0
Port Number of connecting the Hotel
Printer Command Service
Note 2
b
1
b
2
b
3
Hotel Printer In Service
0/1 = Not Required/Required
b
4
Automatic Wake-Up – Hotel Attendant Assistant
0/1 = Out/In Service
b
5
Setting the priority for Guest Station in Automatic Wake-Up
0/1 = Out/In Service
b
6
Wake-Up information (time, station number, etc.) printout
0/1 = Out/In Service
b
7
Floor Service
0/1 = Out/In Service
b
2
b
1
b
0
b
2
b
1
b
0
0
0
0
= Not used
1
0
0
= 4 digits
0
0
1
= 1 digit
1
0
1
= 5 digits
0
1
0
= 2 digits
1
1
0
= 6 digits
0
1
1
= 3 digits
1
1
1
= Not used
b
6
b
5
b
4
b
6
b
5
b
4
0
0
0
= Not used
1
0
0
= 4 digits
0
0
1
= 1 digit
1
0
1
= 5 digits
0
1
0
= 2 digits
1
1
0
= 6 digits
0
1
1
= 3 digits
1
1
1
= Not used
b
2
b
1
b
0
b
2
b
1
b
0
0
0
0
= Port 0
0
1
1
= Port 3
0
0
1
= Port 1
1
0
0
= Port 4
0
1
0
= Port 2
1
0
1
= Port 5
1
1
0
= Port 6
1
1
1
= Port 7