ND-70348 (E)
CHAPTER 4
Page 187
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
TENANT
NUMBER
(TN)
1 – 63
SYSTEM
DATA
INDEX
(INDEX)
0 – 15
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
2
3
b
0
SMDR service
0/1 = Out/In Service
0
b
1
Not used
0
b
2
0
b
3
b
4
Account Code when Authorization Code is in
service
0/1 = Not Required/Required
b
5
Code type
0/1 = Authorization Code/Forced Account Code
0
b
6
Not used
b
7
Output of SMDR Station to Station Connection
Data
0/1 = Not Required/Required
SYSTEM
TN
IMX
1 ~ 63