ND-70348 (E)
CHAPTER 4
Page 621
Revision 3.0
ACRD
4. Data Sheet
CDN
CONNECTION RT No.
(C_RT) 1-1023
FUNCTION (FUNC)
1
TF - Type of Trunk
0 - 2 = -
3 = Bothway Trunk (BWT)
3
3
3
3
3
3
2
TCL - Trunk Class (Fixed “4”)
0-3= -
4=Fusion Trunk
5-31= -
4
4
4
4
4
4
3
RLP - Trunk Release Pattern
(Fixed “2”)
0-1 = -
2 = First party Release
3 = -
2
2
2
2
2
2
4
SMDR-
Detailed Billing Information
(Fixed “0”)
0 = SMDR is out of service
1 = SMDR is in service
0
0
0
0
0
0
5
LSG
-
Line Signal
0-11 = -
12 = B-channel
13 = D-channel
14, 15 = -
6
PAD
-
PAD control
0 = Depending on the assignment of PAD
parameter in ARTD command.
1 = 8dB for sending, 0dB for receiving.
2 = 4dB
3 = 8dB for sending, 12 dB for receiving.
4 = 8dB
5 = Not used
6 = Not used
7 = 0dB
Note:
Standard data=7 (0 dB)
7
TRKS
-
Trunk Selection Sequence
0 = Select from the trunk which becomes
idle first
1 = Select from the trunk which becomes
idle last
0
0
0
0
0
0
8
TC/EC
0 = No MPC/EC
1 = EC
2 = MPC
3 = Not used