ND-70348 (E)
CHAPTER 4
Page 521
Revision 3.0
ASHUL
ASHUL: Assignment of Station Hunting Group-UCD for LDM
1. General
This command assigns the data related to the Uniform Call Distribution (UCD) service feature for each Node
by using Telephone Number. The data is written in Local Data Memory (LDM).
2. Precautions
1.
This command is also used to modify and delete the UCD service related data.
2.
The maximum number of stations within a UCD group is 100.
3.
A maximum of 63 UCD groups can be arranged per a Node.
4.
The UCD pilot station (controlling station) is assigned at the TELN parameter.
5.
Press ESC to skip forward to the WRT? text box when all the desired stations have been entered.
6.
Assign the AUADN command if the Delay Announcement-UCD service feature is required.
7.
Assign the AUCDN command if the peripheral threshold listed below is required:
(a) The number of call in UCD queuing which is used for the UCD Peg Count
(b) The threshold of the UCD Call Waiting Lamp (which can be accommodated on a D
term
) starts to
flash
(c) Denial of the MCI call result text of the call terminated to the UCD group
8.
Assign AUOGL command if the Overflow-UCD service feature is required.
9.
When assigning the AUADL/AUCDL/AUOGL commands, the User Group Number (UGN) and the UCD
Pilot station (controlling station) number (TELN) assigned in this command are used to specify the UCD
group.
10. This command is available since Release 9 software enhancement.