ND-70348 (E)
CHAPTER 4
Page 600
Revision 3.0
ARDN
ARDN: Assignment of Remote Control Day/Night
1. General
This command is used to assign the data related to the Centralized Day/Night Mode Change service feature.
2. Precautions
1.
This command is used only at the Main office which controls the Day/Night mode for the satellite office
via the CCIS link.
2.
When there are multiple satellite offices created by grouping tenant numbers, the mode can be changed on
all the satellite offices or on a per tenant basis.
3.
For the Main office, the related indexes of the ASYD command are as follows:
SYS1, INDEX18, bit6 (Day/Night change of satellite office) 0/1 = Out/In service
SYS1, INDEX75, bit0 (ARSC command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit1 (ASFC command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit2 (ATNR command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit3 (ATDP command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit4 (AEFR command Day/Night table) 0/1 = common/separate
For the Satellite office, the related indexes of the ASYD command are as follows:
SYS1, INDEX18, bit7 (Day/Night change is executed by the Main Office) 0/1 = Out/In service
SYS1, INDEX19, bit0-3 (Tenant (TN=1-15) of the main office to which the satellite office belongs)
SYS1, INDEX75, bit0 (ARSC command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit1 (ASFC command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit2 (ATNR command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit3 (ATDP command Day/Night table) 0/1 = common/separate
SYS1, INDEX75, bit4 (AEFR command Day/Night table) 0/1 = common/separate
3. Data Entry Instructions
POINT CODE INDEX
(INDEX)
0-15
POINT CODE
(PC)
1-16383
REMARKS
INDEX
Enter an arbitrary unique number within
the range from 0 to 15.
PC
Enter the PC of satellite office.