ND-70348 (E)
CHAPTER 4
Page 662
Revision 3.0
ASYDN
Note 1:
Total Billing means “telephone that called last.”
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
(MDATA)
DATA
0/1
BIT
1
29~32
00
Not used
33
0
b
0
Not used
0
b
1
0
b
2
b
3
Telephone Subject to Total Billing (when b6 = 1)
0
0 = Telephone that called first.
0
1 = Telephone that called last.
1
0 = First telephone after the call has been handled by ATT.
1
1 = Last telephone after the call has been handled by ATT.
b
4
b
5
Billing for Transferred Incoming Call
0/1 = Split/Total Billing
Note 1
b
6
Billing for Transferred Outgoing Call
0/1 = Split/Total Billing
Note 1
0
b
7
Not used
34~40
00
Not used
41
OG Queuing Override - DDD Seizing Timer
(for Netfusing Service)
Timer Counter (TC) is to be assigned a value from 01 Hex to
7F Hex.
Timer Value Setting is (TC)
×
30 sec.
Note:
When this data (TC) is 00 Hex, default data of 3 min-
utes is set.
b
4
b
3