ND-70348 (E)
CHAPTER 4
Page 100
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF (Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
35
b
0
Not used
b
1
b
2
b
3
b
4
b
5
b
6
b
7
36
00
Not used
37
00
Not used
38
b
0
Stand-Alone Fault Printer Accommodation Designation
“1” is to be assigned to each bit corresponding to the Port Num-
ber of the IOC circuit card.
b
0
= Port 0
b
1
= Port 1
b
2
= Port 2
b
3
= Port 3
b
4
= Port 4
b
5
= Port 5
b
6
= Port 6
b
7
= Port 7
Note:
Usually, Port 1 is used for System Message Printer.
b
1
b
2
b
3
b
4
b
5
b
6
b
7