ND-70348 (E)
CHAPTER 4
Page 101
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA 0/1
BIT
1
39
b
0
System Message Automatic Output Designation for Stand-Alone Fault
Printer
“1” is to be assigned to each bit corresponding to the Port Number of the
IOC circuit card.
b
0
= Port 0
b
1
= Port 1
b
2
= Port 2
b
3
= Port 3
b
4
= Port 4
b
5
= Port 5
b
6
= Port 6
b
7
= Port 7
Note:
Usually, Port 1 is used for System Message Printer; assign the
same data as INDEX 38.
b
1
b
2
b
3
b
4
b
5
b
6
b
7
40
00
Not used
41
b
0
~
b
6
OG Queuing Override
–
DDD Seizing Timer
Timer Counter (TC) is to be assigned a value from 01 Hex to 7F Hex.
Timer Value Setting is (TC)
×
30 sec.
Note:
When this data (TC) is 00 Hex, default data of 3 minutes is set.
0
b
7
Not used
42
b
0
~
b
1
Not used
b
2
System Message “5-Q”, ACD MIS Lock Up is to be output
0/1 = Invalid/Valid
Note:
This data is available since software Release 5 and ACD soft-
ware Release 1.
b
3
Trunk Hold Tone sending from #0 circuit of DAT card
0/1 =-/External Hold Music
b
4
Digit addition using “AUNE”
0/1 = No/Yes
b
6
Not used
b
7
SST, SPDT Tone
0/1 = Continuous/Burst