ND-70348 (E)
CHAPTER 4
Page 197
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 31
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
3
0
b
0
ON Time is to be assigned a
value from 1 Hex to F Hex
(1~15). (Unit of Time is Sec-
ond.)
Timer Value for Ringer used
for Incoming Trunk Calls
(Ringer Pattern 0)
Note:
Normally, this Index
is assigned data 21
Hex. (1 sec.-ON, 2
sec.-OFF)
b
1
b
2
b
3
b
4
OFF Time is to be assigned a
value from 1 Hex to F Hex
(1~15). (Unit of Time is Sec-
ond.)
b
5
b
6
b
7
1
b
0
ON Time is to be assigned a
value from 1 Hex to F Hex
(1~15). (Unit of Time is Sec-
ond.)
Timer Value for Ringer
used for Station Calls
(Ringer Pattern 1)
Note:
Normally, this Index
is assigned data 42
Hex. (2 sec.-ON, 4
sec.-OFF)
b
1
b
2
b
3
b
4
OFF Time is to be assigned a
value from 1 Hex to F Hex
(1~15). (Unit of Time is Sec-
ond.)
b
5
b
6
b
7