ND-70348 (E)
CHAPTER 4
Page 426
Revision 3.0
ARTDN
LGRT
1-899
FUNCTION
REMARKS
116
PREF
0
0
0
0 Always assign data “0”.
117
DFS
0
0
0
0 Always assign data “0”.
118
BOB
Broad Band
0=64K
1= N
×
64K
0
0
0
0
119
HO1CH
0
0
0
0 Always assign data “0”.
120
IFR
Indonesia Compulsion Cut Service
0= Out of Service
1= In Service
0
0
0
0 Always assign data “0”.
121
CONV
SMDR Called Number Conversation
0= Conversation Number
1= In Service
122
ORRT
Originally Trunk Information
0= Out of Service
1= In Service
123
CNI
Calling Number Identification Format
0= No ANI
1= Feature Group D Format
2= Not used
3= Not used