ND-70348 (E)
CHAPTER 4
Page 171
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
245
b
0
Miscellaneous Timer Counter
(MTC) is to be assigned a value
from 0 Hex to F Hex (0–15).
Timer for Delay An-
nouncement – Atten-
dant (Duration of Music
on Hold)
Note:
When this data
is 00 Hex, de-
fault data is
automatically
set to 30 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be as-
signed one of the following val-
ues:
b
6
b
5
b
4
b
6
b
5
b
4
0
0 0
= –
1 0 0 = –
0
0 1
= –
1 0 1 = –
0
1 0
= –
1 1 0 = –
0
1 1
= 2 sec. 1 1 1 = –
b
5
b
6
b
7
Not used
246
b
0
While engaging in a two-party call with a station/trunk, the
Attendant places the call on hold by pressing either the AN-
SWER key or the Incoming Call Identification (ICI) key and
answers the next call.
0/1 = Not Available/Available
b
1
While engaging in a three-way call with station/trunks, the
Attendant exits from the call by depressing either ANSWER
key or ICI key and answers an incoming call terminated next.
0/1 = Not Available/Available
0
b
2
Attendant Delay Announcement
0/1= Multiple Playback/Single Playback
b
3
MCI Expansion
0/1 = Normal/Expanded
b
4
Process of incoming calls (Ring Down), after they encounter
their 1st and 2nd receiver time-out, in a sequence of Auto-
mated Attendant
0/1 = Forced Release/Transfer to ATT
b
5
Not used
b
6
b
7
1ST.
2ND.
TONE