ND-70348 (E)
CHAPTER 4
Page 96
Revision 5.0
ASYD
Note:
When “1” has been assigned to b
7
, the station number of Station A (Called Party), as shown in the figure
below, is provided to the SMDR equipment.
Index 20 Bit 7 = 0
Station B or RT + TRK of Calling Party is provided as originator of call on SMDR
output.
b
7
= 1
Station A is output as the originator in both cases.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA 0/1
BIT
1
20
0
b
0
Not used
0
b
1
0
b
2
0
b
3
0
b
4
0
b
5
b
6
Line Circuit Reverse Relay Control when Reorder Tone is connected to a
station / trunk
0/1 = In/Out of Service
b
7
Billing Party for a call transferred by Call Forwarding
–
Outside Service
Note
0 = The Billing Party is the originator of the transferred call.
1 = The Billing Party is the station that has set Call Forwarding
–
Outside
service.
STN A
STN A
STN B
TRK A
Outside Party
Calling Party
Outside Party
* STN A has set Call
Forwarding-Outside service.