ND-70348 (E)
CHAPTER 4
Page 131
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
131
0
b
0
Not used
0
b
1
0
b
2
0
b
3
b
4
Sender Prepause Timer:
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0~15).
For 2nd DT trunks, the send-
er waits until this timer ex-
pires before sending dialed
digits.
Timer Value Setting is MTC
×
512 msec.
Note:
When this data is 00
Hex, the following
default data is auto-
matically set:
DP = 2.9 sec.
PB = 2.5 sec.
b
5
b
6
b
7
132
0
b
0
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0~15).
MFC Response Timer
MTC
×
2 sec.
0
b
1
0
b
2
0
b
3
b
4
Sender Inter Digit Timer for DP:
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0~15).
The interval between dialed
digits.
Timer Value Setting is:
10 pps; MTC
×
1 sec.
20 pps; MTC
×
1 sec.
Note:
When this data is 00
Hex, 860 msec./10
pps and 460 msec./
20 pps are automati-
cally set.
b
5
b
6
b
7
OGT START
DIAL PULSE
“3”
OGT START
“3”
“2”
SENDING
DIAL PULSE