ADA1_T: Assignment of DTE Attribute Data 1 – Telephone Number
1. General
This command is used to assign and delete Attribute Data 1 for each terminal (DTE). Attribute Data 1 is stored
as the office data of the switching unit, and is rarely modified in normal operation. Attribute Data 2, on the other
hand, is stored on the data terminal side and is modified in the course of operation. The station data can be as-
signed by using Telephone Number.
2. Precautions
1.
Only the Telephone Numbers assigned by the ALGSN command can be used. Telephone Numbers by the
ALGSL command is not available in this command.
2.
In case logging in to a LN, only the Telephone Numbers allocated to the stations within the logged-in
node can be used in this command. Also, when logging in to the NCN, the data memory of the whole
nodes in the network can be written.
3.
This data can be set for the following TEC (Telephone Equipment Class):
TEC = 13 (DTE via
D
term
)
Refer to ASDT/AAST command.
4.
This command is available since Release 8 software enhancement.
3. Data Entry Instruction
See the data sheet on the next page.