ND-70348 (E)
CHAPTER 4
Page 580
Revision 3.0
ANCD
ANCD: Assignment of Night Connection Data
1. General
This command is used when the Power Failure Transfer (PFT) circuit card is controlled by the external key.
2. Precautions
1.
When the “PFT control by the external key” is required, the following data assignments are needed:
(a) AUNT command, TYPE=2 (PFT)
(b) AEKD command
(c) ANCD command
(d) ACSI command, CSI=4 (Direct-in Termination (Night Mode))
3. Data Entry Instructions
MODULE
GROUP
(MG)
PORT NUMBER
OF PFT CARD
(PORT)
0-11
PFT CARD
NUMBER
(NCU PKG)
0-3
ROUTE
NUMBER
(RT)
1-255
REMARKS
TRUNK
NUMBER
(TK)
MG/NCU/ PKG
Enter the data assigned by the AUNT command.
PORT
The port parameter corresponds to the circuit
number of the PFT card.
RT/TK
Enter the trunk route number (RT) and the trunk number
(TK) connected to the corresponding circuit number of PFT
card.