ND-70348 (E)
CHAPTER 4
Page 663
Revision 3.0
ASYDN
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0–1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
(MDATA)
DATA
0/1
BIT
1
42
b
0
Not used
b
1
Not used
b
2
Not used
b
3
Not used
b
4
Not used
b
5
Not used
b
6
Not used
b
7
SST, SPDT Tone
0/1 = Continuous/Burst
43
00
Not used
46
00
Not used
47
b
0
Traffic Measurement Indication
0/1 = CCS Indication/Erlang Indication
Note:
Available since Release 4 software.
0
b
1
~
b
6
Not used
b
7
Traffic Measurement for Terminal and Route Traffic
(ATRFN)
0/1 = Out/In Service
Note:
Available since Release 4 software.
48
00
Not used
58
00
Not used
59
0
b
0
Not used
0
b
1
Not used
b
2
DID Busy Condition 0/1 = No Tone/ROT
0
b
3
Not used
0
b
4
Not used
0
b
5
Not used
0
b
6
Not used
0
b
7
Not used
60
0
b
0
~
b
2
Not used
b
3
UCD Queuing via Netfusing 0/1 = Available/Unavailable
0
b
4
~
b
7
Not used
61-64
00
Not used
65
Maximum Number of Routes 1-255=01-FF Hex.
66
00
Not used
~
~
~
~
~
~