ND-70348 (E)
CHAPTER 4
Page 267
Revision 3.0
AOPRL
AOPRL: Assignment of Outgoing Pattern Routing Data for LDM
1. General
This command is used to assign the LCR/LCRS routing pattern for each Outgoing Route Selection Pattern Rout-
ing (OPR) number. This command is required when LCR/LCRS activates via Netfusing Link.
2. Precautions
1.
The OPR parameter corresponds to the one assigned by the AFRSL command.
2.
The TDPTN parameter is intermediate data to assign the ATCP command. The ATCP command is used to
assign the time pattern.
3.
The PNL parameter is intermediate data to assign the AADCL command. The AADCL command is used
to assign the additional numbers to transmit.
4.
The applicable number of additional digits (DC) by the AADCL command varies depending on the PNL
data. A maximum of 4 digits of DC is available when the PNL is assigned the range from 1 to127, and a
maximum of 24 digits of DC is available when the PNL is assigned the range from 128 to 999.
5.
The E parameter is an indicator label of the RA. When E=1 is assigned, more RA assignments are required
until E=0 has assigned.
6.
The overflow tone can be applied to the originating party if an alternate trunk route has been seized. The
OVFT parameter designates whether the overflow tone is or is not provided.
7.
The PRSC parameter is referred to as RSC2 of the AEFR command if the “LCR-Controlled Alternate
PRSC service is provided. Enter 0 (leave it blank) when the service is not required.