ACMO
ACMO: Assignment of Clocked Manual Override
1. General
This command is used to assign the Clocked Manual Override data, which is used for changing routes during a
specific day and specific time period, such as holiday (Month/Day/Hour/Minute).
2. Precautions
1.
The BLOCK parameter is a data index (0-7). A maximum of eight kinds of Clocked Manual Override Data
can be assigned.
2.
The PTN parameter corresponds to the TDPTN parameter assigned by the AOPR/AOPRL/ASDC com-
mand.
3.
The Clocked Manual Override data assigned by ACMO command has priority over the Time Pattern data
assigned by the ATCP command.
4.
Time is designated in Military Time. “24” cannot be used as Hour designation.
5.
A single set of PTN (Pattern Number) and START/END date and time is to be assigned to a BLOCK Num-
ber. Also the same PTN can be specified to multiple BLOCK Numbers.
6.
“PTN=0” is used in default setting (in unspecified time period). Thus the assignment “PTN=0” means
nothing in this command.
3. Data Entry Instructions
Enter a block number for a Clocked Manual Override data
Month/Day
ex) 09/20=September, 20th
BLOCK
BLOCK NUMBER
(BLOCK)
0-7
PATTERN NUMBER
(PTN)
0-7
Pattern number (0-7) assigned by the AOPR/AOPRL/ASDC command.
PTN
Hour/Minute
TIME
DATE
START
END
DATE
TIME
DATE
TIME
REMARKS
09
20
17
00
09
21
09
00