Installation
2-26 Manual # 42-02-2P24
Cover (HPV 900/900PM)
LEDs indicate the status of the drive:
• Ready: Ready but not actually providing current to the motor.
• Run: Providing current to the motor.
• Program Invalid: No valid software on the drive control board.
• Fault: Drive has declared a fault.
• Torque Limit: The drive has reached its torque limit. See drive manual.
Drive Motor/Encoder Setup Overview
Figure 2.10 Magnetek Motor/Encoder Setup Overview
A1 Drive menu
Contract Car Speed
Contract Motor Speed
Brake Pick Time
0.0
Encoder Pulses
Mtr Torque Limit
Regen Torq Limit
A2 S-Curves menu
Accel Rate 0
0.00
Decel Rate 0
0.00
Accel Jerk Out 0
0.00
Decel Jerk In 0
0.00
Decel Jerk Out 0
0.00
A4 Power Convert menu
Input L-L Volts
A5 Motor Menu
Motor ID
(4 or 6 pole)
Rated Mtr Power
Rated Mtr Volts
Rated Excit Freq
Rated Motor Curr
Motor Poles
Rated Mtr Speed
C1 User Switches menu
Spd Command Src
Serial
Run Command Src
Serial
Spd Reg Type
Elev Spd Reg
Cont Confirm Src
External
Pre-Torque Source
Serial
Fault Reset Src
Serial
Ramped Stop Sel
Ramp On Stop
Ramp Down En Src
Run Logic
Motor Ovrld Sel
Fault At Stop
Serial Mode
Mode 1
HPV900: C4 Analog Outputs menu
Analog Output 1 (TB1-33) Speed Command
Analog Output 2 (TB1-35) Speed Feedback
HPV900II: C4 Analog Outputs menu
Analog Output 1 (TB2-1) Speed Command
Analog Output 2 (TB2-8) Speed Feedback
HPV600: C4 Analog Outputs menu
Analog Output 1 (A0-A1) Speed Command
Analog Output 2 (A0-A2) Speed Feedback
HPV600PM: C4 Analog Outputs menu
Analog Output 1 (TB6-A01) Speed Command
Analog Output 2 (TB6-A02) Speed Feedback
900/900PM: C2 Logic Inputs menu
Logic Input 1 (TB1-1)
Drive Enable
Logic Input 2 (TB1-2)
Contact Cfirm
Logic Input 3 - 9
No Function
900II: C2 Logic Inputs menu
Logic Input 1 (TB1-6)
Drive Enable
Logic Input 2 (TB1-7)
Contact Cfirm
Logic Input 3 - 9
No Function
600/600PM: C2 Logic Inputs menu
Logic Input 1 (TB1-16)
Drive Enable
Logic Input 2 (TB1- 7)
Contact Cfirm
Logic Input 3 - 9
No Function
900/900PM: C3 Logic Outputs menu
Logic Output 1 (TB1-14) Ready To Run
Logic Output 2 (TB1-15) Run Commanded
Logic Output 3 (TB1-16) Speed Reg Rls
Logic Output 4 (TB1-17) Ramp Down En
Relay Coil 1 (TB2-51/52/53) Ready to Run
Relay Coil 2 (TB2-54/55/56) Speed Reg Rls
900II: C3 Logic Outputs menu
Logic Output 1 (TB1-13) Ready To Run
Logic Output 2 (TB1-14) Run Commanded
Logic Output 3 (TB1-15) Speed Reg Rls
Logic Output 4 (TB1-16) Ramp Down En
Relay Coil 1 (TB2-27/28/29) Ready to Run
Relay Coil 2 (TB2-30/31/32) Speed Reg Rls
600/600PM: C3 Logic Outputs menu
Logic Output 1 (TB1-9)
Ready To Run
Logic Output 2 (TB1-10) Run Commanded
Logic Output 3 (TB1-11) Speed Reg Rls
Logic Output 4 (TB1-12) Ramp Down En
Relay Coil 1 (TB2-51/52/53) Ready to Run
Relay Coil 2 (TB2-54/55/56) Speed Reg Rls
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...