PC Board Quick References
5-63
5
Motion 4000
Normal Operation
During normal operation, I/O LEDs will be lighted when the associated I/O is active (dimmer
when the output is active; brighter when the input is active). The SPA processor LED will be
continuously lighted. If I/O LEDs remain in a static condition or the SPA processor LED is not
continuously on:
• Press the RST button on the board. The I/O LEDs will all cycle and the board will resume
operation.
ICE-COP-2 Board Details
•
24V Inputs Only:
Typical circuit for terminals
I1 through I16.
•
24V Outputs Only:
Typical circuit for terminals
O1 through O16
.
•
24V Inputs/Outputs Only:
Typical circuit for terminals
IO1 through IO16.
S2 Switches
Eight-position DIP switch S2 allows a unique address to be set for each
COP board, places the board in CAN or iControl communication mode, sets the board input
threshold, and determines the CAN baud rate (when CAN is enabled).
ment, ICE-COP-2 Boards” on page A-29.
• RS485 or CAN Communication
• For Motion controls, the board must be set to use CAN communication.
• CAN Enable: Verify/set switch 8 to the ON position.
• Motion Input Threshold Detection
On COP-2 boards with software version 1.1 or later, the input threshold level may be set to
900 or 700mV using DIP switch rocker 5.
• Board revision X2-1 or greater: Recommended, rocker 5 OFF: 900mV (default)
• Board revision X2-0: Recommended, rocker 5 ON: 700mV
• Motion Board Addressing
For Motion controls, each COP-2 board used must have a unique address.
• Addressing - switches 1, 2, and 3:
S2
Front COP Boards
Rear COP Boards
Board
SW1
SW2
SW3
SW1
SW2
SW3
1
Off
Off
Off
Off
Off
On
2
On
Off
Off
On
Off
On
3
Off
On
Off
Off
On
On
Call Button / Lamp
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...