User Interface
4-140 Manual # 42-02-2P24
Profile Compensation, 193
Selects the method used to implement Profile Advance,
parameter 140 (used to advance application of the speed profile to compensate for internal con-
trol lag within the elevator drive). Helpful during runs in which the elevator does not achieve
stable contract speed (i.e., short runs) and pattern transition command/drive reaction lag may
cause a “bump” in the ride.
• Fixed: Compensates for drive control lag using the fixed value entered in parameter 140,
Profile Advance through all stages of control.
Recommended for new installations.
Too much compensation can cause an abrupt transition between acceleration and deceler-
ation at peak speed. Using fixed compensation will probably require a little experimenta-
tion to achieve good starts and a smooth ride but will provide better results once dialed in.
Required when a Magnetek HPV600, HPV900, or QUATTRO drive is used.
• Dynamic: Compensates for drive control lag during the deceleration stage only using a
variable percentage of the value entered in parameter 140, Profile Advance.
Recom-
mended to provide backwards compatibility when upgrading Motion 4000
software in existing installations.
(Previous versions always used Dynamic compen-
sation; fixed compensation was not an option.)
Normal Brake Pick Voltage, 194
When a CAN controlled brake module is used, this
setting determines pick voltage applied to the normal machine brake.
Normal Brake Hold Voltage, 195
When a CAN controlled brake module is used,
this setting determines hold voltage applied to the normal machine brake.
Normal Brake Relevel Voltage, 196
When a CAN controlled brake module is used,
this setting determines relevel voltage applied to the normal machine brake.
Normal Brake Lift Rate, 197
When a CAN controlled brake module is used, this set-
ting determines the lift rate of the normal machine brake. 100% = fastest lift rate.
Normal Brake Drop Rate, 198
When a CAN controlled brake module is used, this
setting determines the drop rate of the normal machine brake. 100% = fastest drop rate.
Emergency Brake Type, 199
This setting selects the method of control for the emer-
gency brake. (CAN) Module or Discrete. Appears only if parameter 186 has been used to select
an emergency brake type.
Emergency Brake Pick Voltage, 200
Only if Module is selected in 199. Determines
the pick voltage applied to the emergency machine brake.
See “Calibration (CAN Only)” on
Emergency Brake Hold Voltage, 201
Only is Module is selected in 199. Deter-
mines the hold voltage applied to the emergency machine brake.
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...