PC Board Quick References
5-67
5
Motion 4000
Figure 5.10 MC-CPI Serial Car Operating Panel Board
Caution
This system is designed for 24 VDC circuits maximum. Do not
connect 120VAC or DC to any terminal on this board at any time.
J3
- To next MC-CPI
board (RJ11)
Inputs only
24 VDC max.
6W max.
To MC-LSI board in
Cartop box or
MC-CPI board -
J2
From Power
Supply -
J5
+24VDC in
COM
Outputs only
24 VDC max.
6W max.
I/O only
24 VDC max.
6W max.
+24VDC
COM
To next board -
J10
Reset button
SW1
Board Address
JP1
- Bus termination
on last board
+24VDC
COM
J6
- Customer
Load Supply
SPA ON indicator