Landing/Positioning System
2-75
2
Motion 4000
3. Adjust the distance between sensor and tape. Up to a travel height of 110 meters, we rec-
ommend an offset of 1 inch (25 mm) with the polymer guide removed. (See the illustra-
tion below.) Verify that the offset measures 1.0 inches at both the top and the bottom of
the sensor. This will ensure steady, even contact between the steel side of the tape and
the polymer guide of the sensor.
4. Re-attach the polymer guide with the tape resting in the guide slot.
1.0 inches (25 mm)
ELEVATOR CAR
Tape
Sheet-plastic membrane
Polymer guide
Tape (magnetic band towards sensor)
Sheet-plastic membrane
CAR
Sensor body
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...