Troubleshooting
5-58 Manual # 42-02-2P24
HC-UIO Universal Input/Output Board
Depending upon the software installed, HC-UIO boards may be used for programmable inputs
and outputs (16 per board), car and hall calls, door operator interface, or dispatching.
Figure 5.7 HC-UIO Universal Input/Output Board
Switches
• DIP SW1:
• Switches 1 through 6 = Board ID (
see “HC-UIO Board Call Assignments” on page 5-59
and (
see “HC-UIO Spare Input / Output Assignments” on page 5-61
• Switches 7 & 8 = Baud rate (
see “HC-UIO Board DIP SW1 Switches 7 and 8” on page 5-
• Switch 9 = Input levels (
see “HC-UIO Board DIP SW1 Switch 9 for I/O Boards” on
• Sw2: RST - Processor reset
Jumpers
• JP2: Internal CAN Network Termination
• JP3: External CAN Network Termination
• JP6: Selects voltage reference
• A = 120Vac power supplied by J4 (default)
• B = 24Vdc power supplied by CAN bus
Test Points
• GND: Digital Ground - 0 V
• +5V: +5 Vdc measured between this test point and TP GND.
• 1: 1 Bus (common)
J7: External CAN connection
J2: Internal CAN connection
J4
J3:24 - 120V AC or DC Inputs / Outputs
Indicators
JP3
JP2
JP6
TP GND
CPU ON LED
SW1
TP1
SW2: RST
J1
TP +5V
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...