F7 Settings Record
A-15
A
Motion 4000
73
U/DNT4 Option: If up and down position 4
normal terminal switches are positioned in
software by the system, they are Virtual. If
mechanical switches are installed, they are
Physical. If position 4 normal terminal
switches are not used, select Unused.
74
U/DNT5 Option: If up and down position 5
normal terminal switches are positioned in
software by the system, they are Virtual. If
mechanical switches are installed, they are
Physical. If position 5 normal terminal
switches are not used, select Unused.
75
UETS Speed: Speed in feet per minute which
the car must be below when tripping the up
emergency terminal switch. Must never be in
excess of 95% of contract speed. Determined
by contract speed and position of the switch.
76
UETS Distance: Distance in Inches from the
top terminal floor level position at which the
up emergency terminal switch is positioned.
Approximately half the distance needed by the
drive to decelerate to zero speed from contract
speed.
77
UETS Delta Distance: Distance in Inches on
either side of the up emergency terminal
switch position inside which the car must
detect the up emergency terminal switch. If
not, the car will perform an emergency stop.
78
UETS Delta Speed: Delta speed is generally
unused in applications below 400 FPM. Delta
Speed provides an “adder” to UETS speed.
UETS speed and Delta speed together may not
exceed 95% of contract speed. If you are trip-
ping an ETS fault during car setup, you can
choose to use this adder or you can choose to
temporarily disable the ETS switches by set-
ting them to Unused until you have sufficient
control of the car.
79
UNTS1 Speed: Speed in feet per minute which
the car must be below when tripping the
UNTS1 switch.
80
UNTS1 Distance: Distance in inches from the
top terminal floor level position at which a vir-
tual UNTS1 switch is positioned.
81
UNTS1 Delta Distance: Distance in inches on
either side of the UNTS1 switch inside which
the car must detect the switch. If not, the car
will perform an emergency slow down.
Table A.3 F7 Parameter Log
ID#
Description
Setting
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...