Installation
2-76 Manual # 42-02-2P24
Caution
It is critical to ensure that the sensor is installed so
that any mechanical contact between tape and sensor
head is between the steel band and the polymer sensor
guide. Adjust for a horizontal offset of 1 inch (25 mm)
between the sensor metal face and the magnetic band
so that contact between the steel side and the polymer
guide is firmly forced.
When properly installed, looking at the top of the sensor,
there will be a slight gap between the magnetic band and
the body of the sensor. Refer to the illustration below.
Steel Side
Magnet Side
Steel Side
Magnet Side
With the sensor guide
re-installed, the tape
should arc gently
away from the car at
the top and bottom,
forcing the steel side
of the tape firmly
against the polymer
guide.
Be certain that the
sensor head is
plumb with the
tape. Check top
and bottom to be
certain it is not out
at the bottom while
appearing correctly
offset at the top.
A rocking car with
roller guide or iso-
lation mount prob-
lems can exhibit
sensor head align-
ment issues at dif-
ferent points in the
hoistway.
gap between tape magnetic
surface and body of sensor/
plastic membrane
Correct
Tape
Sheet-plastic membrane
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...