F1: Program Mode
4-49
4
Motion 4000
• EQ SHUTDOWN AT LANDING?
• If yes, when the EQI input is activated, the elevator will proceed to the nearest landing,
stop, open its doors, and shut down.
• If no, the elevator will react as above but will return to service rather than shutting
down.
• CORRECTION AWAY FROM CW?
• If yes, when the SSI input is activated, the elevator will pause (freeze) momentarily,
correct to the nearest landing in the direction away from the counterweight, then con-
tinue as determined by the EQ SHUTDOWN AT LANDING selection.
• If no, when the SSI input is activated, the elevator will not consider counterweight
location when proceeding as determined by the EQ SHUTDOWN AT LANDING selec-
tion. Default should be No for A17.1 code. If the CWI input is never activated, the car
will proceed to the next available landing, open the doors, and shut down
• EQ SHUTDOWN PH1 FIRE SERV?
• If yes, earthquake shutdown will occur even if the car is on Phase 1, fire return. Default
should be Yes for all codes.
• EQ SHUTDOWN PH2 FIRE SERV?
• If yes, earthquake shutdown will occur even if the car is on Phase 2, in-car firefighter
service. Default should be Yes for all codes.
Additional Car Options
• ETS SWITCHES REQUIRED
• Unused parameter. Set to No.
• HOISTWAY ACCESS? (YES/NO)
• Set to YES if job has Hoistway Access operation.
• TOP ACCESS? (F/R)
• Set to the riser in which the hall access switch is located.
• BOTTOM ACCESS? (F/R)
• Set to the riser in which the hall access switch is located.
• DOOR POSITION MONITORS: (NONE/FRONT/REAR/BOTH)
• If job uses door position monitor switches, set accordingly.
• FRONT DOOR CLOSE LIMIT?
• Set to the door close limit signals used by this car. (DCL for door close limit switch. GS
and DCAB for gate switch and door closed bottom access. None.)
• REAR DOOR CLOSE LIMIT?
• Set to the door close limit signals used by this car. (DCLR for door close limit switch.
GSR and DCABR for gate switch and door closed bottom access. None.)
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...