![Motion Control Engineering Motion 4000 Manual Download Page 407](http://html1.mh-extra.com/html/motion-control-engineering/motion-4000/motion-4000_manual_1837882407.webp)
Motion Brake Module
5-85
5
Motion 4000
J4, J5
J4 is a modular, CAN connector for serial module control. (See preceding informa-
tion about termination enabling jumper JP1.) J5 provides auxiliary connections that can be
used to directly lift the machine brake, regardless of controller status.
The level of the pick voltage is adjusted using potentiometer R67. The maximum pick voltage
range is determined by input voltage to the module and whether the input connection is single
phase, FCL1/FCL2, or three phase, FCL1/FCL2/FCL3.
J3
J3 provides control signals to the TC-FCP board and accepts feedback voltages from the
TC-FCP board.
J6
J6 accepts DC power voltages from the logic power supply board (TC-LPS).
Middle Board, TC-LPS
1 and 2 bus power connections from the controller are connected to TC-LPS connector
J1. As viewed from the front of the connector, pinout is:
This board provides DC power to the logic board through connector J2.
Bottom Board, TC-FCP
The FCP board transforms AC input power (single or three phase) into the DC output voltage
required to control the brake. The in-line connectors on the board are sized to handle higher
voltage and current.
RELEV
Discrete Relevel control input from controller (V AC/DC)
FLT
Overload fault output
COM
Common connection for PICK, HOLD, RELEV, FLT
1
1 Bus (common) from elevator controller
2
2 Bus (120VAC) from elevator controller
TS2
Thermal switch input from sensor on module heat sink
TS1
Thermal switch input from sensor on module heat sink
Table 5.34 J5 Auxiliary Brake Connections
Pin
Function
BRBP1
With BRBP3, connects to auxiliary brake pick switch
BRBP2
With BRBP4, energizes brake coil when active
BRBP3
With BRBP1, connects to auxiliary brake pick switch
BRBP4
With BRBP2, energizes brake coil when active
Table 5.35 In-Line Connectors Pin Assignment
Pin
Function
J2, SN1
With SN2, connection point for external filter provided with unit
J2, SN2
With SN1, connection point for external filter provided with unit
J2, SN3
With J3, SN4, connection point for user-provided external filter
Table 5.33 J1 Pin Assignment
Pin
Function
1
1
2
2
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...