Magnetek Parameters Table
A-7
A
Motion 4000
Up/Dwn Threshold Detection threshold, up or down direction
%
0 - 9.99
1.00
Mtr Torque Limit
Motoring torque limit. Torque Limit LED will
light when this limit is reached.
%
0 - 250.0
250.0
Regen Torq Limit
Regenerating torque limit. Torque Limit LED
will light when this limit is reached.
%
0 - 250.0
250.0
Flux Wkn Factor
Defines torque limit at higher speeds
%
60.0 - 100.0
75.0
Ana 1 Out Offset
Subtracts an effective voltage to actual analog
output 1
%
-99.9 - 99.9
0.00
Ana 2 Out Offset
Subtracts an effective voltage to actual analog
output 2
%
-99.9 - 99.9
0.00
Ana 1 Out Gain
Scaling factor for analog output 1
-
0 - 10.0
1.0
Ana 2 Out Gain
Scaling factor for analog output 2
-
0 - 10.0
1.0
Flt Reset Delay
Time Before a fault is automatically reset
sec
0 - 120
5
Flt Reset / Hour
Number of faults allowed to reset automati-
cally per hour
fault 0 - 10
3
Up to SPD. Level
The logic output function is true when the
motor speed is above the user specified speed
defined here
%
0 - 110.00
080.00
Mains DIP Speed
When enabled by the Main DIP Speed (A1)
parameter, speed is reduced by this percent
when an undervoltage alarm is declared
%
5 - 99.9
25.00
Run Delay Timer
Delays drive recognition of RUN signal.
sec
0.00 - 0.99
0.00
AB Zero Spd Lev
Auto Brake Function - N/A to MCE products
%
0.00 - 2.00
0.00
AB Off Delay
N/A to MCE products
sec
0.00 - 9.99
0.00
Contactor DO Dly
N/A to MCE products
sec
0.00 - 5.00
0.00
TRQ Lim Msg Dly
Time duration drive is in torque limit before
Hit Torque Limit message displayed.
sec
0.50 - 10.00
0.50
SER2 INSP SPD
Defines the serial mode 2 Inspection
(only serial mode 2)
ft/
min
0 - 100
30
SER2 RS CRP SPD Creep speed used in “rescue mode”
ft/
min
0 - 100
10
SER2 RS CPR Time Maximum time drive will continue to run at
rescue creep speed (only serial mode 2)
sec
0 - 200
180
SER2 FLT TOL
Maximum time that may elapse between valid
run time messages before a serial fault is
declared (only serial mode 2)
sec
0.0 - 2.0
0.04
Rollback Gain
Ant-rollback gain
-
1 - 99
1
Notch Filter Frq
Notch Filter Center Frequency
Hz
5 - 60
20
Notch Filt Depth
Notch filter maximum attenuation
%
0 - 100
0
MSPD Delay 1-4
Recognition time delay for a defined multistep
speed command
sec
0.00 - 10.0
0.00
A2 S-Curves
Accel Rate 0
Acceleration rate #0
ft/s
2
0 - 7.99
3.00
Decel Rate 0
Deceleration rate #0
ft/s
2
0 - 3.999
3.00
Accel Jerk in 0
Rate of increase of acceleration, up to ACCEL
Rate, when increasing elevator speed
ft/s
3
0 - 8.0
8.0
Table A.2 Magnetek AC Drive Table
#
Operator
Display
Parameter Description
Unit
Setting
Range
MCE
Defaults
Field Set
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...