Troubleshooting
5-86 Manual # 42-02-2P24
Figure 5.18 External Filtering
J3, SN4
With J2, SN3, connection point for user-provided external filter
J3, FCO- With FCO+, provides power to energize brake coil under normal logic conditions
J3, FCO+ With FCO-, provides power to energize brake coil under normal logic conditions
J5, DT1
Factory Only. Production testing.
J5, DT2
Factory Only. Production testing.
J5, FCL1
AC input, with J6, FCL2 for single-phase use or J6, FCL2/FCL3 for three-phase use
J6, FCL2
AC input, with J5, FCL1 for single-phase use or J5, FCL1/J6 FCL3 for three-phase use
J6, FCL3
AC input, with J5, FCL1 and J6, FCL2 for three-phase use.
Table 5.35 In-Line Connectors Pin Assignment
Pin
Function
Module
FCO+
SN4
SN2
SN1
SN3
FCO-
Filter
Resistance value: 3 - 5 x coil resistance
Optional
Filter
Brake Coil