4. HOW TO USE THE POINT TABLE
4 - 23
2) Incremental value command method ([Pr. PT01] = _ _ _ 1)
The position data of the incremental value command method is the sum of the position data of
consecutive point tables.
The following shows how to set.
Point table setting
Dwell Auxiliary
function
1 or more
1
a) Positioning in a single direction
The following shows an operation example with the set values listed in the table below.
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
Auxiliary
function
M code
(Note 2)
1 5.00
3000 100 150
100 1
05
2 6.00
2000
150 200
200
1
10
3 3.00
1000
300
100 Disabled
0 (Note 1)
15
Note 1. Always set "0" to the auxiliary function of the last point table among the consecutive point tables.
2. M code will be available in the future.
Servo motor speed
Forward
rotation
Reverse
rotation
Position address
Selected point table No.
ST1
(Forward rotation start)
(Note 1)
ON
OFF
PT0 (Point table No. output 1)
to PT4 (Point table No. output 5)
(Note 2)
M code output (Note 3)
Speed
Acceleration/deceleration time constant
of point table No. 1
Acceleration/deceleration time constant
of point table No. 2
Speed
Speed (1000)
Acceleration/deceleration time constant
of point table No. 3
6.00
0
5.00
11.00
14.00
1
1
05
3.00
0 r/min
(3000)
(2000)
Note 1. Switching on ST2 (Reverse rotation start) starts positioning in the reverse rotation direction.
2. For MR-JE-_A servo amplifiers, up to four points of DO are available; therefore, PT0 to PT4 cannot be outputted
simultaneously.
3. M code will be available in the future.
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...