5. HOW TO USE THE PROGRAM
5 - 12
3) Program example 3
Using the S-pattern acceleration/deceleration time constants reduces abrupt movements at
acceleration or deceleration. When the "STD" command is used, [Pr. PC03 S-pattern
acceleration/deceleration time constant] does not function.
Command Description
SPN (1000)
Servo motor speed
1000 [r/min]
a)
STC (100)
Acceleration/deceleration time constant
1000 [ms]
b)
STD (10)
S-pattern acceleration/deceleration time
constant
10 [ms]
c)
MOV (2000)
Absolute value travel command
2000 [×10
STM
μ
m] d)
STOP Program
stop
c)
c)
c)
a) Servo motor speed
(1000 r/min)
b) Acceleration/
deceleration time constant
(1000 ms)
b) Acceleration/deceleration time constant
(1000 ms)
d) Absolute value travel command
(2000 × 10
STM
μ
m)
Servo motor
speed
c) S-pattern acceleration/
deceleration time constant
(10 ms)
Reverse rotation
0 r/min
Forward rotation
(b) Continuous travel commands (MOVA/MOVIA)
POINT
A combination of "MOV" and "MOVIA" commands, and a combination of "MOVI"
and "MOVA" commands are not available.
The "MOVA" command is a continuous travel command for the "MOV" command. After the travel
with the "MOV" command is executed, the travel with "MOVA" command will be executed
continuously without a stop.
The speed specified by the "MOVA command" is enabled from the deceleration start point of the
preceding "MOV" or "MOVA" command.
The acceleration/deceleration time constants for the preceding "MOV" command is also applied to
those for the "MOVA" command.
The "MOVIA" command is a continuous travel command for the "MOVI" command. After the travel
with the "MOVI" command is executed, the travel with "MOVIA" command will be executed
continuously without a stop.
The speed specified by the "MOVIA command" is enabled from the deceleration start point of the
preceding "MOVI" or "MOVIA" command.
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...