3. DISPLAY AND OPERATION SECTIONS
3 - 17
3.1.6 Parameter mode
(1) Parameter mode transition
After selecting the corresponding parameter mode with the "MODE" button, pressing the "UP" or
"DOWN" button changes the display as shown below.
[Pr. PB01]
[Pr. PA02]
[Pr. PA01]
I/O setting
parameters
[Pr. PD01]
[Pr. PD02]
[Pr. PD47]
[Pr. PD48]
[Pr. PC01]
[Pr. PC02]
[Pr. PC79]
Extension setting
parameters
[Pr. PC80]
[Pr. PB02]
[Pr. PB63]
[Pr. PB64]
To status display mode
[Pr. PA31]
Basic setting
parameters
[Pr. PA32]
Extension setting 2
parameters
[Pr. PE01]
[Pr. PE02]
[Pr. PE63]
[Pr. PE64]
Extension setting 3
parameters
[Pr. PF01]
[Pr. PF02]
[Pr. PF47]
[Pr. PF48]
Gain/filter
parameters
MODE
Positioning control
parameters
[Pr. PT01]
[Pr. PT02]
[Pr. PT47]
[Pr. PT48]
UP
DOWN
From alarm mode
(2) Operation method
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the positioning mode (point table method) with [Pr. PA01 Operation mode]. Press
"MODE" to switch to the basic setting parameter display.
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
The set value of the specified parameter number blinks.
Press "SET" twice.
To decide the value , press "SET".
Press "UP" six times.
During blinking, the set value can be changed.
Use "UP" or "DOWN".
( _ _ _ 6: Positioning mode (point table method))
……
……
……
To shift to the next parameter, press the "UP" or "DOWN" button.
After changing [Pr. PA01], cycle the power to enable the setting.
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...