7. PARAMETERS
7 - 63
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PT17
LMNL
Software limit
-
(lower three
digits)
Set an address decreasing side of the software stroke limit.
Upper and lower are a set.
Setting address:
Upper 3
digits
Lower 3
digits
[Pr. PT17]
[Pr. PT18]
The stop method depends on "Stop method selection at software limit detection" of
[Pr. PD30]. The initial value is "Quick stop (home position erased)".
Setting a same value with "Software limit +" will disable the software stroke limit.
(Refer to section 7.4.)
Set a same sign for [Pr. PT17] and [Pr. PT18]. A different sign will be recognized as
minus sign data.
When changing the direction to address increasing, change it from the + side of the
software limit ([Pr. PT15] and [Pr. PT17]). An incorrect order of the setting will trigger
[AL. 37]. Therefore, cycling power may be required after [Pr. PT15] to [Pr. PT18] are
all set.
The unit will be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with
the setting of [Pr. PT01].
Setting range: -999999 to 999999
0
Refer to
Function
column
for unit.
PT18
LMNH
Software limit
-
(upper three
digits)
PT19
*LPPL
Position
range output
a
(lower three
digits)
Set an address increasing side of the position range output address.
Upper and lower are a set. Set a range which POT (Position range) turns on with [Pr.
PT19] to [Pr. PT22].
Setting address:
Upper 3
digits
Lower 3
digits
[Pr. PT19]
[Pr. PT20]
The unit will be changed to 10
STM
[
μ
m], 10
(STM-4)
[inch], 10
-3
[degree], or [pulse] with
the setting of [Pr. PT01].
Set a same sign for [Pr. PT19] and [Pr. PT20]. Setting a different sign will trigger [AL.
37 Parameter error].
When changing the setting, be sure to set the lower three-digit data first and then the
upper three-digit data.
When changing the direction to address decreasing, change it from the - side of the
position range output address ([Pr. PT21] and [Pr. PT22]). An incorrect order of the
setting will trigger [AL. 37]. Therefore, cycling power may be required after [Pr. PT19]
to [Pr. PT22] are all set.
Setting range: -999999 to 999999
0
Refer to
Function
column
for unit.
PT20
*LPPH
Position
range output
a
(upper three
digits)
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...