7. PARAMETERS
7 - 56
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PD42
*DIA4
Input signal
automatic on
selection 4
Select input devices to turn on automatically.
_ _ _ x For manufacturer setting
0h
_ _ x _
0h
_ x _ _
(HEX)
_ _ _ x (BIN): DI0 (Point table No./program No. selection 1)
0h
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ _ x _ (BIN): DI1 (Point table No./Program No. selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): DI2 (Point table No./Program No. selection 3)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): DI3 (Point table No./Program No. selection 4)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ For manufacturer setting
0h
Convert the setting value into hexadecimal as follows.
0
Initial value
BIN HEX
Input device
0
0
0 0
0
0
DI2 (Point table No./Program No. 3)
DI0 (Point table No./Program No. 1)
DI1 (Point table No./Program No. 2)
DI3 (Point table No./Program No. 4)
0
PD44
*DI11H
Input device
selection 11H
Any input device can be assigned to the CN1-10 pin and the CN1-37 pin.
_ _ x x Not used with the positioning mode.
00h
x x _ _ Positioning mode - Device selection
Refer to table 7.10 in [Pr. PD04] for settings.
When "00" is set, PP/PP2 (Forward rotation pulse/Manual pulse generator) will be
assigned.
The CN1-37 pin is available with servo amplifiers manufactured in May, 2015 or
later.
20h
PD46
*DI12H
Input device
selection 12H
Any input device can be assigned to the CN1-35 pin and the CN1-38 pin.
_ _ x x Not used with the positioning mode.
00h
x x _ _ Positioning mode - Device selection
Refer to table 7.10 in [Pr. PD04] for settings.
When "00" is set, NP/NP2 (Reverse rotation pulse/Manual pulse generator) will be
assigned.
The CN1-38 pin is available with servo amplifiers manufactured in May, 2015 or
later.
2Bh
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...