10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
10 - 21
10.2.4 Test operation mode
POINT
The test operation mode is for checking an operation. Do not use it for an actual
operation.
If communication stops for 0.5 s or longer during the test operation, the servo
motor decelerates to a stop, resulting in servo-lock. To prevent this, keep the
communication all the time by checking the status display, etc.
The test operation mode can be started even in operation. In this case,
switching to the test operation mode will shut off the base circuit to coast the
servo motor.
(1) How to prepare and cancel the test operation mode
(a) Preparation of the test operation mode
Set the test operation mode type with the following procedure.
1) Setting of test operation mode
Transmit the command [8] [B] + data No. [0] [0] + data to set the test operation mode.
Command
Data No.
Transmission data
Setting test operation mode
[8] [B]
[0] [0]
0004
Output signal (DO) forced output (Note)
0005 Single-step
feed
Note. Refer to section 10.2.5 for the output signal (DO) forced output.
2) Check of test operation mode
Read the test operation mode set for the slave station, and check that it is set correctly.
a) Transmission
Transmit command [0] [0] + data No. [1] [2].
Command Data
No.
[0] [0]
[1] [2]
b) Return
The slave station returns the preset operation mode.
0
0
Reading test operation mode
0: Normal mode (not test operation mode)
1: JOG operation
2: Positioning operation
3: Motor-less operation
4: Output signal (DO) forced output
5: Single-step feed
0
(b) Cancel of test operation mode
To stop the test operation mode, transmit the command [8] [B] + data No. [0] [0] + data. Turn off the
servo amplifier before switching the operation mode from the test to the normal.
Command
Data No.
Transmission data
Setting test operation mode
[8] [B]
[0] [0]
0000
Test operation mode cancel
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...