6.2 Mark detection
6.2.1 Current position latch function
POINT
The current position latch function can be used with the point table method and
the program method. However, the current position latch function is disabled in
the following condition.
Home position return
Manual operation (excluding home position return)
The latched actual current position data can be read with communication
commands.
For the servo amplifiers with software version B6 or earlier, the latched position
data is not compatible with the current position of the state monitor when the roll
feed display function is enabled. Disable the roll feed display function to
compare the current data of the state monitor and the latched position data.
The read latched position data is equal to the travel distance as the starting
point is set to "0" when the roll reed display function is enabled. The output
value is the same as the current position of the state monitor.
When the mark detection signal turns on, the current position is latched. The latched data can be read with
communication commands.
(1) Communication command
Reads mark detection data.
Command Data
No.
Description
Control mode
Frame
length
CP/
BCD
C
L
P
S
[1] [A]
[0] [0]
MSD (Mark detection) rising latch data (data part)
8
[0] [1]
MSD (Mark detection) falling latch data (data part)
[0] [2]
MSD (Mark detection) rising latch data (data part + additional information)
12
[0] [3]
MSD (Mark detection) falling latch data (data part + additional information)
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...