4. HOW TO USE THE POINT TABLE
4 - 19
2) Absolute value command method ([Pr. PT01] = _ _ _ 1)
While the servo motor is stopped under servo-on state, switching on ST1 (Forward rotation start)
or ST2 (Reverse rotation start) starts the automatic positioning operation.
The following shows a timing chart.
MD0
(Operation mode
selection 1)
ON
OFF
ON
OFF
SON (Servo-on)
ON
OFF
ST1
(Forward rotation start)
ST2
(Reverse rotation start)
ON
OFF
Point table No.
Reverse
rotation
Servo motor speed
ON
OFF
INP (In-position)
ON
OFF
CPO (Rough match)
MEND
(Travel completion)
ON
OFF
PT0 (Point table No.
output 1) to PT4 (Point
table No. output 5)
(Note 2)
M code output (Note 3)
ON
OFF
RD (Ready)
ALM (Malfunction)
ON
OFF
3 ms or longer
3 ms or longer
Point table No. 1
Point table No. 2
1
2
1
2
M code of point table No. 1
3 ms or shorter
5 ms or longer
5 ms or longer
(Note 1)
Forward
rotation
0 r/min
Note 1. The detection of external input signals is delayed by the set time in the input filter setting of [Pr. PD29].
Considering the output signal sequence from the controller and signal variations due to hardware,
configure a sequence that changes the point table selection earlier.
2. For MR-JE-_A servo amplifiers, up to four points of DO are available; therefore, PT0 to PT4 cannot be
outputted simultaneously.
3. M code will be available in the future.
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...