10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)
10 - 23
10.2.5 Output signal pin on/off (output signal (DO) forced output)
In the test operation mode, the output signal pins can be turned on/off regardless of the servo status. Disable
the external input signals in advance with command [9] [0].
(1) Selecting the output signal (DO) forced output of the test operation mode
Transmit c [8] [B] + data No. [0] [0] + data "0004" to select the output signal (DO) forced
output.
0
0 4
Setting test operation mode
4: Output signal (DO) forced output
0
(2) External output signal on/off
Transmit the following communication commands.
Command
Data No.
Setting data
[9] [2]
[A] [0]
See below.
b31
b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
CN1 connector pin
Bit
CN1 connector pin
0 49
16
1 24
17
2 23
18
3
19
4
20
5 48
21
6 33
22
7
23
8
24
9
25
10
26
11
27
12
28
13
29
14
30
15
31
(3) Output signal (DO) forced output
To stop the output signal (DO) forced output, transmit command [8] [B] + data No. [0] [0] + data. Turn off
the servo amplifier before switching the operation mode from the test to the normal.
Command
Data No.
Transmission data
Setting test operation mode
[8] [B]
[0] [0]
0000
Test operation mode cancel
Summary of Contents for MR-JE-100A
Page 49: ...2 SIGNALS AND WIRING 2 28 MEMO...
Page 73: ...3 DISPLAY AND OPERATION SECTIONS 3 24 MEMO...
Page 213: ...5 HOW TO USE THE PROGRAM 5 68 MEMO...
Page 275: ...6 APPLICATION OF FUNCTIONS 6 62 MEMO...
Page 355: ...8 TROUBLESHOOTING 8 8 MEMO...
Page 359: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO...
Page 391: ...10 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 10 32 MEMO...