5. HOW TO USE THE PROGRAM
5 - 19
2) Program example 2
Command Description
SPN (1000)
Servo motor speed
1000 [r/min]
STC (20)
Acceleration/deceleration time constant
20 [ms]
MOVI (1000)
Incremental value travel command
1000 [×10
STM
μ
m]
TIM (200)
Dwell
1: 200 [ms]
a)
OUTON (1)
Switch on OUT1 (Program output 1).
b)
MOVI (500)
Incremental value travel command
500 [×10
STM
μ
m]
STOP Program
stop
b)
a) 200 ms
Servo motor
speed
ON
OFF
OUT1
(Program output 1)
Reverse rotation
0 r/min
Forward rotation
3) Program example 3
Command Description
SPN (1000)
Servo motor speed
1000 [r/min]
STC (20)
Acceleration/deceleration time constant
20 [ms]
MOVI (1000)
Incremental value travel command
1000 [×10
STM
μ
m]
OUTON (1)
Switch on OUT1 (Program output 1).
a)
TIM (200)
Dwell
200 [ms]
b)
MOVI (500)
Incremental value travel command
500 [×10
STM
μ
m]
STOP Program
stop
a)
b) 200 ms
Servo motor
speed
ON
OFF
OUT1
(Program output 1)
Reverse rotation
0 r/min
Forward rotation