FX2N-16CCL-M CC-Link System Master Block
System Configuration 3
3-2
When using a FX
2N
, FX
2NC
or a FX
1N
PLC
1) Connection of remote I/O stations (up to 7 stations)
2) Connection of remote device stations (up to 8 stations)
Up to 8 remote device stations can be connected without regard to the number of remote I/O
stations shown in 1).
3.2
Applicable PLC
Number of I/O points in PLC (including vacant
numbers and extension I/O points)
points
Number of points occupied by FX
2N
-16CCL-M
8 points
Total number of points occupied by other
special extension PLCs
points
32
×
Number of remote I/O stations
points
[Total]
≤
256: FX
2N/2NC
Series PLC
≤
128: FX
1N
Series PLC
Number of remote device stations occupying 1
station
1 station
×
modules stations
Number of remote device stations occupying 2
stations
2 stations
×
modules stations
Number of remote device stations occupying 3
stations
3 stations
×
modules stations
Number of remote device stations occupying 4
stations
4 stations
×
modules stations
[Grand total]
stations
≤
8
Table 3.1:
Series name
Applicable version
FX
1N
Manufacturer’s serial number: 08**** or later
(Approximate production period: August, 2000 or later)
FX
2N
System version V 2.20 or later
(Approximate production period: July, 2000 or later)
FX
2NC
(FX
2NC
-CNV-IF is required.)
FX
3U
All
Summary of Contents for FX2N-16CCL-M
Page 4: ...FX2N 16CCL M CC Link System Master Block ii ...
Page 6: ...FX2N 16CCL M CC Link System Master Block iv ...
Page 34: ...FX2N 16CCL M CC Link System Master Block System Configuration 3 3 14 MEMO ...
Page 66: ...FX2N 16CCL M CC Link System Master Block Specification 4 4 32 MEMO ...
Page 144: ...FX2N 16CCL M CC Link System Master Block Programming 9 9 16 MEMO ...
Page 172: ...FX2N 16CCL M CC Link System Master Block Communication in Compound System 12 12 10 MEMO ...
Page 192: ...FX2N 16CCL M CC Link System Master Block Appendix 14 14 4 MEMO ...
Page 193: ......