FX2N-16CCL-M CC-Link System Master Block
Data Link Procedure 8
8-6
Number
Name
Description
5)
Mode setting
switch
Sets the operation status of the module. (Default setting at shipment: 0)
Number
Name
Description
0
Online
Sets connection to data link.
1
(Unusable)
⎯
2
Offline
Sets disconnection from data link.
3
Line test 1
Refer to Section 8.7.1.
4
Line test 2
Refer to Section 8.7.2.
5
Parameter
verification test
Refer to Section 8.8.
6
Hardware test
Refer to Section 8.3.
7
(Unusable)
Setting error (The SW LED indicator turns ON.)
8
(Unusable)
Cannot be set because it is already used inside.
9
(Unusable)
Cannot be set because it is already used inside.
A
(Unusable)
Cannot be set because it is already used inside.
B
(Unusable)
Setting error (The SW LED indicator turns ON.)
C
(Unusable)
Setting error (The SW LED indicator turns ON.)
D
(Unusable)
Setting error (The SW LED indicator turns ON.)
E
(Unusable)
Setting error (The SW LED indicator turns ON.)
F
(Unusable)
Setting error (The SW LED indicator turns ON.)
6)
Transmission
speed setting
switch
Sets the transmission speed of the module. (Default setting at shipment: 0)
Number
Setting contents
0
156kbps
1
625kbps
2
2.5Mbps
3
5Mbps
4
10Mbps
5
Setting error (The SW and L ERR. LED indicators turn ON.)
6
Setting error (The SW and L ERR. LED indicators turn ON.)
7
Setting error (The SW and L ERR. LED indicators turn ON.)
8
Setting error (The SW and L ERR. LED indicators turn ON.)
9
Setting error (The SW and L ERR. LED indicators turn ON.)
MODE
12
345678
9
0
A
BC
DE
F
B RATE
0
2
1
3
4
156K
625K
2.5M
5M
10M
1
2 3 4
5
6
78
9
0
Summary of Contents for FX2N-16CCL-M
Page 4: ...FX2N 16CCL M CC Link System Master Block ii ...
Page 6: ...FX2N 16CCL M CC Link System Master Block iv ...
Page 34: ...FX2N 16CCL M CC Link System Master Block System Configuration 3 3 14 MEMO ...
Page 66: ...FX2N 16CCL M CC Link System Master Block Specification 4 4 32 MEMO ...
Page 144: ...FX2N 16CCL M CC Link System Master Block Programming 9 9 16 MEMO ...
Page 172: ...FX2N 16CCL M CC Link System Master Block Communication in Compound System 12 12 10 MEMO ...
Page 192: ...FX2N 16CCL M CC Link System Master Block Appendix 14 14 4 MEMO ...
Page 193: ......