FX2N-16CCL-M CC-Link System Master Block
Functions 5
5-23
2) Link special registers (SW)
The table below shows the link special registers (SW) related to the temporary error invalid
station specification function.
*1 Only the bit of the head station number is set to ON.
Table 5.4:
Number
BFM
number
Hex.
Name
Description
SW0003
603
H
Specification of
multiple temporary
error invalid stations
Selects whether or not two or more stations are
specified as temporary error invalid stations.
00 : Specifies two or more stations stored in SW0004.
01 to 15: Specifies one station (station No. 1 to 15).
* The number specifies the station number of a station
to be specified as a temporary error invalid station.
SW0004
604
H
Specification of
temporary error invalid
station
*1
Specifies temporary error invalid stations.
0: Does not specify as a temporary error invalid
station.
1: Specifies as a temporary error invalid station.
Numbers 1 to 15 above indicate the station numbers
SW0049
649
H
Temporary error invalid
station request result
Stores the execution result of the request for
temporary error invalid station by SB0004.
0 : Normal
Any value other than 0: Stores an error code. (Refer
to Section 13.3.)
SW004B
64B
H
Temporary error invalid
station cancel request
result
Stores the execution result of the request for cancel of
temporary error invalid station by SB0005.
0 : Normal
Any value other than 0: Stores an error code. (Refer
to Section 13.3.)
SW007C
67C
H
Temporary error invalid
station specification
status
*1
Stores the temporary error invalid station specification
status.
0: Not specified as temporary error invalid station
1: Specified as temporary error invalid station
Numbers 1 to 15 above indicate the station numbers
Point
1) When both the request for temporary error invalid station and the request for
cancel of temporary error invalid station are given at the same time, the request
for cancel of temporary error invalid station has the priority.
2) In a station occupying two or more stations, only the head station number is
effective.
b15 b14 b13 b12
~
b3
b2
b1
b0
SW0004
⎯
15
14
13
~
4
3
2
1
b15 b14 b13 b12
~
b3
b2
b1
b0
SW007C
⎯
15
14
13
~
4
3
2
1
Summary of Contents for FX2N-16CCL-M
Page 4: ...FX2N 16CCL M CC Link System Master Block ii ...
Page 6: ...FX2N 16CCL M CC Link System Master Block iv ...
Page 34: ...FX2N 16CCL M CC Link System Master Block System Configuration 3 3 14 MEMO ...
Page 66: ...FX2N 16CCL M CC Link System Master Block Specification 4 4 32 MEMO ...
Page 144: ...FX2N 16CCL M CC Link System Master Block Programming 9 9 16 MEMO ...
Page 172: ...FX2N 16CCL M CC Link System Master Block Communication in Compound System 12 12 10 MEMO ...
Page 192: ...FX2N 16CCL M CC Link System Master Block Appendix 14 14 4 MEMO ...
Page 193: ......