3
-
19
(2) Preparing to Assemble Renewal Kit (2)
Remove the attachment, which was mounted at the time of shipment, to separate it into:
①the attachment (base), and
②the attachment (amplifier base).
(3) Mounting the Replacing Servo Amplifier on Renewal Kit
1. Remove the 2 grounding terminal screws on the
replacing servo amplifier in advance.
Note 1 Make sure to remove the grounding
terminal screws in advance.
2.As shown in the drawing below, mount the replacing
servo amplifier on the amplifier base ②. To mount
the replacing servo amplifier, use the screws
among the accessories in the package (M5×12; 3
screws).
3.Mount the mounting bracket ③ on the replacing
servo amplifier, and fasten it with the grounding
terminal screws that you removed in advance and
with the screws among the accessories in the
package (M3×6; 2 screws).
* You have no extra space between the servo amplifier and Renewal Kit. To mount the servo
amplifier, use such a Phillips head screwdriver as shown below.
Replacing servo amplifier
③Mounting bracket
②Amplifier base
(Note 1)
Grounding terminal screw
(on the replacing servo amplifier)
①Base
Phillips head screwdriver
Approx. 200mm
3 - 19
Summary of Contents for MR-J2S CP-S084 Series
Page 9: ...A 8 MEMO A 8 ...