3
-
10
・Type of the servo amplifier・・・The case of Type B with the amplifier capacity of 7kW or lower
You are going to connect the currently used cable to the conversion cable.
●
The connectors (CN3, CN2, CN1A, and CN1B) on the conversion cable are
all in the same shape. Use caution not to make an incorrect connection.
If you make an incorrect connection, the servo amplifier may be broken.
The connectors (CN3 and CN2) on servo amplifier MR-J2S-_B are all in the same shape. If you connect
a currently used cable to a wrong connector and turn on power, the amplifier, the motor, and/or the
like may be broken due to the difference in voltage.
C
N2
CN
3
制御信号変換ケーブル
(SC-J2SBJ4CT1C03M)
エンコーダ変換ケーブル
(SC-J2SJ4ENC03M)
CN3用
変換ケーブル側
既設制御信号ケーブル
既設エンコーダケーブル
既設ケーブル側
SSCNET変換ユニット
(MR-J4-T20)
CN1A用
CN1B用
既設制御信号ケーブル
●
Do not fasten the encoder conversion cable and the control signal
conversion cable on a power cable or on a drive cable. Dosing so may cause
an incorrect operation.
Use cable ties (accessories in the package) to fasten and fix the cables
on the control signal conversion cable of Renewal Kit or on the currently
used control signal connection cable.
The connectors are all in the same
shape. Use caution not to make an
incorrect connection.
CN10A
CN10B
Side of the Conversion Cable
Side of the Currently Used Cable
Control signal conversion cable
Encoder conversion cable
SSCNET conversion module
For CN3
For CN1A
Currently used control
signal cable
Currently used encoder
cable
Currently used control
signal cable
For CN1B
CAUTION
CAUTION
3 - 10