6
-
5
Indication
Title
Error
Cause
Countermeasures
1. A connector on the servo amplifier and
the conversion cable of Renewal Kit
are disconnected.
Make a correct connection.
2. The conversion cable of Renewal Kit
and a currently used cable are
disconnected.
Make a correct connection.
3. The encoder conversion cable on the
Renewal Kit side and a currently used
cable are incorrectly connected.
Make a correct connection.
4. External 24V DC power is not working.
AL.E6.1
Forced-stop alarm EM2/EM1 is off.
5. The 24V DC power supply cable is not
connected to the control signal
conversion cable.
Supply 24V DC power.
* Turn on the external 24V DC power
source at the same time with the servo
amplifier. If the external power source is
slow to start up, AL.E6.1 occurs.
* For the troubleshooting at the time of a startup, see section 4.3.