3
-
14
(2) Preparing to Assemble Renewal Kit (2)
Remove the attachment, which was mounted at the time of shipment, to separate it into:
① the base, and
② the amplifier base.
(3) Mounting the Replacing Servo Amplifier on Renewal Kit
1. Remove the 2 grounding terminal screws on the
replacing servo amplifier in advance.
Note 1
Make sure to remove the grounding terminal
screws in advance.
2. As shown in the drawing on the right side,
mount the replacing servo amplifier on the
amplifier base ②. To mount the replacing
servo amplifier, use the screws among the
accessories in the package (M5×12; 3 screws).
3. Mount the mounting bracket ③ on the
replacing servo amplifier, and fasten it with
the grounding terminal screws that you removed
in advance and with the screws among the
accessories in the package (M3×6; 2 screws).
* You have no extra space between the servo amplifier and Renewal Kit. To mount the servo
amplifier, use such a Phillips head screwdriver as shown below.
Replacing servo amplifier
③Mounting bracket
②Amplifier base
(Note 1)
Grounding terminal screw
(on the replacing servo amplifier)
①Base
Phillips head screwdriver
Approx. 200mm
3 - 14